+27 11 452 8116info@hcppumps.co.za
HCP Pumps SASOUTH AFRICA

AFU Series
Vortex pumps

Submersible sewage pumps with recessed vortex impellers for water containing large solids. For permanent and portable installation in residential, commercial and agricultural sewage applications.

0.4 to 11 kWMotor power
50 to 100 mmDischarge sizes
100 mmMax. solids
HCP AFU Series vortex sewage pumps

Models and specifications

Select a model to see its data. In the model code, 2 means two pole and 4 means four pole; L means a large-solids version. We will confirm suitability against your required flow, head and site conditions.

28 models · Voltage options update with your selection.

50AFU4.4

Maximum head and maximum flow are separate limits; they are not reached at the same time. Use the performance curve in the catalogue to confirm your duty point.

Where two weights are given, they are single phase / three phase, excluding cable.

Fits a guide rail: The 80 and 100 mm models, plus 50AFU4.4, 50AFU4.8, 50AFU2.4L and 50AFU2.8L. See the Guide Rail System

View all model specifications
AFU Series models, from the HCP specification table
ModelPowerVoltagesDischargeBest efficiency pointMax headMax flowSolidsWeight
50AFU4.40.4 kW220, 380 V50 mm / 2″250 L/min at 3.5 m5.5 m400 L/min50 mm30/28 kg
50AFU4.4F0.4 kW220, 380 V50 mm / 2″250 L/min at 3.5 m5.5 m400 L/min50 mm30/28 kg
50AFU4.80.75 kW220, 380 V50 mm / 2″300 L/min at 5 m7.5 m500 L/min50 mm30/29 kg
50AFU4.8F0.75 kW220, 380 V50 mm / 2″300 L/min at 5 m7.5 m500 L/min50 mm30/29 kg
80AFU41.51.5 kW220, 380 V80 mm / 3″600 L/min at 5 m8 m1,100 L/min76 mm46/46 kg
80AFU41.5F1.5 kW220, 380 V80 mm / 3″600 L/min at 5 m8 m1,100 L/min76 mm46/46 kg
80AFU42.22.2 kW380 V80 mm / 3″600 L/min at 7 m10 m1,200 L/min76 mm57 kg
80AFU43.73.7 kW380 V80 mm / 3″600 L/min at 10 m13 m1,500 L/min76 mm66 kg
100AFU45.55.5 kW380 V100 mm / 4″1,000 L/min at 11 m15.5 m2,300 L/min100 mm96 kg
100AFU47.57.5 kW380 V100 mm / 4″1,000 L/min at 13.5 m17.5 m2,600 L/min100 mm105 kg
50AFU2.40.4 kW230, 400 V50 mm / 2″150 L/min at 6 m10 m300 L/min35 mm19/18 kg
50AFU2.80.75 kW230, 400 V50 mm / 2″200 L/min at 8 m14 m360 L/min35 mm20/19 kg
50AFU21.51.5 kW230, 400 V50 mm / 2″200 L/min at 14 m19 m450 L/min35 mm33/29 kg
80AFU21.51.5 kW230, 400 V80 mm / 3″400 L/min at 8.5 m15.5 m750 L/min50 mm35/32 kg
80AFU22.22.2 kW230, 400 V80 mm / 3″400 L/min at 12.5 m19 m850 L/min50 mm38/34 kg
80AFU23.7A3.7 kW400 V80 mm / 3″500 L/min at 16.5 m24 m1,150 L/min50 mm46 kg
80AFU25.55.5 kW400 V80 mm / 3″600 L/min at 20 m27.5 m1,300 L/min50 mm68 kg
80AFU27.57.5 kW400 V80 mm / 3″600 L/min at 24.5 m34 m1,350 L/min50 mm74 kg
80AFU21111 kW400 V80 mm / 3″600 L/min at 32 m40.5 m1,500 L/min50 mm85 kg
50AFU2.4L0.4 kW230, 400 V50 mm / 2″200 L/min at 4 m7 m380 L/min50 mm20/19 kg
50AFU2.8L0.75 kW230, 400 V50 mm / 2″250 L/min at 6 m10.5 m420 L/min50 mm22/21 kg
50AFU21.5L1.5 kW230, 400 V50 mm / 2″250 L/min at 10 m15.5 m470 L/min50 mm34/30 kg
80AFU21.5L1.5 kW230, 400 V80 mm / 3″500 L/min at 4.5 m8 m850 L/min76 mm38/34 kg
80AFU22.2L2.2 kW230, 400 V80 mm / 3″500 L/min at 7 m11 m950 L/min76 mm40/36 kg
80AFU23.7LA3.7 kW400 V80 mm / 3″600 L/min at 11 m16 m1,200 L/min76 mm48 kg
80AFU25.5L5.5 kW400 V80 mm / 3″800 L/min at 13 m21.5 m1,400 L/min76 mm70 kg
80AFU27.5L7.5 kW400 V80 mm / 3″800 L/min at 17.5 m27 m1,600 L/min76 mm76 kg
80AFU211L11 kW400 V80 mm / 3″800 L/min at 25.5 m34.5 m1,850 L/min76 mm87 kg

AFU Series features

Choose from two pole, four pole and large-solids versions, all in heavy-duty cast iron.

Cutaway drawing of an HCP AFU sewage pump showing the cable base, motor protector, motor, mechanical seals and coated casing
  1. Sealed cable entry

    An epoxy resin cable base stops moisture getting into the motor through the core wires.

  2. Automatic motor protection

    An automatic on/off protector stops the motor burning out from high temperature or excess current. Standard on pumps up to 10 HP (7.5 kW).

  3. High-efficiency dry motor

    Varnish-insulated stator coils for good insulation, efficiency and durability.

  4. Double mechanical seals

    Abrasion-resistant silicon carbide seals run in an oil housing, independent of the pumped liquid.

  5. High-solids epoxy coating

    A coating over 70 µm thick protects the cast iron from salty water, industrial wastewater and chemicals.

  • Recessed vortex impellers

    The impeller sits back from the flow, so water containing large solids passes through without clogging.

  • Large-solids versions

    L models pass solids up to 50 or 76 mm; four pole 100 mm models pass up to 100 mm.

  • Two or four pole

    High-torque two pole or four pole motors, to suit the head and flow you need.

  • Quick coupling

    Install on a duck foot bend for easy installation and service. An adaptor bracket fits Flygt and Tsurumi duck foot bends.

Catalogue and specifications

See the manufacturer's catalogue for performance curves, dimensions and technical information.

AFU Series catalogue

50 Hz · PDF

View PDF

Need help choosing your AFU pump?

Share your flow, head and site conditions and our team will help you find the right model.

Request a quote

Tell us about the job and the HCP team will come back to you.

    We only use these details to reply to your request. See our privacy policy.